{"success":true,"data":{"author":"Banuselvasaraswathy Balasubramanian, Prarthana Pillai, Balakumar Balasingam (University of Windsor)","bucketAccessType":"public","bucketName":"bsebench-org/windsor-eis-soc-resttime-2025-raw","bucketPrefix":"","category":"Energy","cloudProvider":"huggingface","createdAt":"2026-11-18T17:37:20.111Z","description":"Electrochemical impedance spectroscopy (EIS) data from the University of Windsor on Molicel INR-21700-P42A cylindrical lithium-ion cells, published on Mendeley Data. A pilot test on one cell swept AC current amplitudes from 1 mA to 1 A over 0.1 Hz to 20 kHz to choose excitation amplitudes. The main variability test measured four cells at 80, 60, 40 and 20% state of charge (SOC), with current amplitudes of 30 mA to 1 A and rest times of 30 minutes, 1 hour and 2 hours before measurement, over 0.01 Hz to 10 kHz, using an Arbin battery cycler and a Gamry 5000P potentiostat. Files are CSV, in folders Factor_CurrentAmplitude (pilot) and Factor_Resttime (variability). Useful for studying how SOC, excitation amplitude and relaxation time shift Nyquist spectra and fitted equivalent-circuit parameters. The BSEBench copy holds the original EISdata.zip with Mendeley provenance files. Licensed CC BY 4.0; cite Balasubramanian, Pillai and Balasingam, Mendeley Data, doi:10.17632/dcbrc4zmc5.2.","displayTitle":"University of Windsor EIS of Molicel INR-21700-P42A Cells across SOC, Current Amplitude and Rest Time (bsebench copy)","doi":"10.17632/dcbrc4zmc5.2","huggingFaceUrl":"https://huggingface.co/datasets/bsebench-org/windsor-eis-soc-resttime-2025-raw","id":"a57989ae-5f03-5655-ba83-006c4617e025","license":"CC-BY-4.0","licenseEvidenceUrl":"https://data.mendeley.com/public-api/datasets/dcbrc4zmc5","objectCountEstimate":9,"probeStatus":"ok","referenceUrl":"https://doi.org/10.17632/dcbrc4zmc5.2","region":"us","schemaCard":{"accessHints":[{"language":"python-datasets","snippet":"from datasets import load_dataset\nds = load_dataset(\"bsebench-org/windsor-eis-soc-resttime-2025-raw\")"},{"language":"python-hub","snippet":"from huggingface_hub import snapshot_download\nsnapshot_download(repo_id=\"bsebench-org/windsor-eis-soc-resttime-2025-raw\", repo_type=\"dataset\")"}],"caveats":["HuggingFace metadata: author=bsebench-org, license:cc-by-4.0, downloads=117"],"format":"mixed","generatedAt":"2026-11-18T17:39:15.000Z","layout":{"example":"data/EISdata.zip","pattern":"{repoId}/{filename}"},"mountPath":"/mnt/archive","sampleHeaders":[{"bytes":"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","encoding":"hex","key":"data/EISdata.zip","truncatedAt":512}],"sampleObjects":["BSEBENCH_SOURCE.json","SHA256SUMS.txt","UPLOAD_MANIFEST.json","data/EISdata.zip","provenance/ZIP_FILE_LIST.json"],"sidecars":[{"bytes":"---\nlicense: cc-by-4.0\ntitle: Experimental Data for Electrochemical Impedance Characterization of Li-ion Batteries Under Varying State of Charge, Current Amplitude and Rest Time\ntags:\n- batteries\n- electrochemical-impedance-spectroscopy\n- lithium-ion-batteries\n- raw-data\npretty_name: Experimental EIS data under varying SOC, current amplitude and rest time\n---\n\n# Experimental Data for Electrochemical Impedance Characterization of Li-ion Batteries Under Varying State of Charge, Current Amplitude and Rest Time\n\nBSEBench status: `raw_mirror_pending_validation`\n\nThis is a raw mirror of the Mendeley Data dataset:\n\n- Source: Mendeley Data\n- Source URL: https://data.mendeley.com/datasets/dcbrc4zmc5/2\n- DOI: https://doi.org/10.17632/dcbrc4zmc5.2\n- Version: 2\n- Published: 2025-12-04T21:52:45.651Z\n- License: CC BY 4.0 (http://creativecommons.org/licenses/by/4.0)\n- Institution: University of Windsor\n- Contributors: Banuselvasaraswathy Balasubramanian, Prarthana Pillai, Balakumar Balasingam\n- Mirror download date: 2026-05-08T10:04:33Z\n\n## Contents\n\n- `data/EISdata.zip`: original Mendeley archive, uploaded without modification.\n- `provenance/mendeley_public_api_dataset.json`: official Mendeley public API metadata snapshot used for verification.\n- `provenance/mendeley_source_page.html`: source page HTML snapshot used for source-page verification.\n- `provenance/ZIP_FILE_LIST.json`: local integrity/listing metadata generated from the ZIP archive.\n- `BSEBENCH_SOURCE.json`: machine-readable provenance and verification record.\n- `SHA256SUMS.txt`: checksums for uploaded files, excluding `SHA256SUMS.txt` itself.\n\n## Source Description\n\nPilot testing – This test was conducted initially to select appropriate AC amplitudes for main EIS experiment.  The tests were conducted on the single cylindrical cell made by Molicel of type INR-21700-P42A, labelled MCLE3231. The test was conducted over a frequency range of 0.1 Hz to 20 kHz using different current amplitudes 1 mA, 2 mA, 3 mA, 4 mA, 5 mA, 10 mA, 15 mA, 20 mA, 25 mA, 30 mA, 50 mA, 100 mA, 500 mA, and 1 A.\nVariability testing - The data was collected on four cylindrical batteries made by Molicel of type INR-21700-P42A labelled as MCLI01, MCLI02, MCLI03, MCLI04. The experiments were performed at different SOC levels (80%, 60%, 40%, and 20%), various current amplitudes (30 mA, 50 mA, 100 mA, 500 mA, and 1 A), and rest times (30 minutes, 1 hour, and 2 hours). All tests were conducted over a frequency range of 0.01 Hz to 10 kHz. \nThe experiments were conducted using two instruments Arbin battery cycler and Gamry 5000P potentiostat. The data collected during pilot testing are stored as CSV (Comma-Separated Values) files inside a folder named “Factor_CurrentAmplitude”. The data collected during the variability testing are in CSV format and are stored in a folder named “Factor_Resttime.”  \n\n## Provenance And Validation\n\nThe mirror was created from the official Mendeley Data page and public file download URL. The downloaded archive size is `341733` bytes and its SHA-256 is `940c468e84666d1d8a42036d9bf53858591a295181d31f0cb1df9544946de414`, matching the checksum reported by Mendeley.\n\nNo source data transformation was performed. This dataset is a raw mirror pending BSEBench validation, and no benchmark, performance, SOTA, or leaderboard claims are made here.\n\n## Citation\n\nBalasubramanian, Banuselvasaraswathy; Pillai, Prarthana; Balasingam, Balakumar (2025), \"Experimental Data for Electrochemical Impedance Characterization of Li-ion Batteries Under Varying State of Charge, Current Amplitude and Rest Time\", Mendeley Data, V2, doi: 10.17632/dcbrc4zmc5.2.\n","encoding":"utf8","key":"README.md","name":"README.md","size":3644,"truncated":false}],"sourceObjectKey":"data/EISdata.zip","starterCell":"from huggingface_hub import hf_hub_download\npath = hf_hub_download(repo_id=\"bsebench-org/windsor-eis-soc-resttime-2025-raw\", filename=\"data/EISdata.zip\", repo_type=\"dataset\")\nprint(path)","starterSamplePath":"BSEBENCH_SOURCE.json","totalObjects":9},"summary":"Electrochemical impedance spectroscopy (EIS) data from the University of Windsor on Molicel INR-21700-P42A cylindrical lithium-ion cells, published on Mendeley Data.","title":"University of Windsor EIS of Molicel INR-21700-P42A Cells across SOC, Current Amplitude and Rest Time (bsebench copy)","updatedAt":"2026-11-18T18:59:00.579Z","visibility":"public","websiteUrl":"https://huggingface.co/datasets/bsebench-org/windsor-eis-soc-resttime-2025-raw"}}